Edit a Double Dowel Machining

Log House Work Drawings

You can change the distance and side of the second dowel by editing the machining library.

  1. Select System | Libraries | Libraries. The Component Libraries database view opens.
  2. Move the cursor on the row LOGMACH_SYSTEM Log Wall Machinings.
  3. Click the Edit Library button. The Log Machining Macro Components database view opens.
  4. Move the cursor over the Double Dowels row.
  5. Select the Machining Data tab of the database view.
  6. Enter a new value in the Machining param field. When the value is positive, the distance is measured to the right, when negative, to the left.
  7. Close the Log Machining Macro Components database view by clicking the OK button.
  8. Close the Component Libraries database view by clicking the OK button.

Note

  • System tab is only available if you are a system administrator.
  • The program will save the changes made in a user-specific database. If the database is not found in the Custom folder, it is first copied from the System folder. Confirm the copying by clicking Yes in the message box.