U Values of Building Components
The U values of building components can be defined in the structure libraries, building parameters or, individually, in the opened buildings. Indicative U values have been determined for the building components in the structure libraries included in the basic software delivery. If the thickness or materials of a component are edited in the building model, the U value will not be updated automatically; it has to be redefined, if necessary.
- Walls
If you edit the number, thickness or materials of structural layers, the U value of the building component is not updated automatically. If necessary, recalculate the U value of the wall and update the new value to the wall properties.
The U value of a wall is displayed in the wall properties if you select all the wall parameters to be displayed in the Wall dialog box.
Editing Wall Properties
Wall ParametersIf you wish to edit the U values in the wall library, note that editing the system wall libraries is not possible. You can only edit customer-specific wall libraries.
- Windows and exterior doors
The U value of a window is displayed in the window properties:
- Click the Properties button in the Window dialog box.
- Select Extra Data.
- The U-value is displayed in the Initial U Value field.
The U value of an exterior door is displayed in the door properties:
- Click the Properties button in the Door dialog box.
- Select the Page 2 tab.
- The U-value is displayed in the U Value field.
Editing the Opening Properties
If U values have not been defined in the window or door library you are using, you can set a default U value for windows and exterior doors by adding the following keywords to the PARAMETERS file of the building:
UVALUE_EXTDOOR "1.0" ! The U value of an exterior door unless defined in the library
UVALUE_WINDOW "1.2" ! The U value of a window unless defined in the library
You can edit the U values defined in the window or door library by editing the library.
Editing a Window or Door Library
The U-value is displayed on the Parameters page of the database view.
- Horizontal structures
The U value of a horizontal structure is displayed in the properties of the structure.
- Select the cross section in the Area Properties dialog box.
- Click the Properties button.
- The U-value is displayed in the U Value field.
Editing the Properties of Horizontal Structures
If you edit the number, thickness or materials of structural layers, the U value of the building component is not updated automatically. You can edit the U values defined in the floors and ceilings library by editing the library. The U value must be determined for the basic layer of a volume.
- Corner running meters, opening perimeters, horizontal structure
perimeters
The corner running meters, opening perimeters and horizontal structure perimeters of space volumes are calculated for the energy report. You can set the default U value for these by adding the following keywords to the building's PARAMETERS file:
UVALUE_CRNEXT "0.0" ! U value of the wall's exterior corner
UVALUE_CRNINT "0.0" ! U value of the wall's interior corner
UVALUE_PRMFLR "0.0" ! U value of the joint between the floor and the wall
UVALUE_PRMFLRINT "0.0" ! U value of the joint between the ceiling and the wall
UVALUE_PRMCLNG "0.0" ! U value of the joint between the roof and the wall
UVALUE_PRMDOOR "0.0" ! U value of the door perimeter
UVALUE_PRMWIN "0.0" ! U value of the window perimeter