Insulation in Section View

Framer

If you wish to display the insulation in a section view on a wall panel drawing, check the following:

Note

  • In the basic software delivery, the section hatch of the insulation is added on the layer 16 in the panel drawing. The layer has been defined in the system settings.

    If the layer has not been defined in the system settings, it is read from the drawing properties of the section hatch. The section hatch has been defined in the insulation library, for example SECT.WOOL. If the drawing properties of the section hatch refer to a line, for example line= WALL.WOOL, the layer is read from the drawing properties of the line WALL.WOOL.