Define IO System to IO List
- Select tab, IO group, IO Cards and Channels.
- Select the properties:
- In IO list, the following are defined (each on it's own database row) : IO cards of the system, terminal blocks of the cards, IO devices, terminal blocks in junction boxes and outlets.
- Several channels of IO card may be needed for outlets and certain IO devices. In those cases, the data of outlet or device is defined in several rows of IO list.
- Inputs and outputs are defined in the IO list card by card in following order:
- First the IO type defining the card.
- A terminal block corresponding to the card's central unit.
- Inputs and outputs of the card in order.
- Terminal blocks of junction boxes can be defined in any order.
One protocol is to define the terminal blocks after all the cards.
Field | Field content |
Position | IO device's position code i.e. location part of device code is defined in position field.
If you wish to define the entity part, it has to be separated before the location part with plus (+) mark. If the field is kept empty, the default is that the position of logic's central unit is considered as the location part in the basic data. Similarly, the logic system ID is considered as the entity part for the device ID if the field is empty. For example 32 or RK2+14 |
IO type | Define in the IO type field a IO type name, that is saved in the device data. You
can select the type from a list by a button IO type.
Combined input or output type IO devices require also, separated with a slash (/), a device code of the device, to which the row's part in question belongs to. For example MGVENT1 tai VKYTK2/3 (Combined input or output) |
Address | If necessary, you enter a new address. Junction block type IO devices require the
device ID unit part of the box in the field.
For example E0.1 or RE0.0 or 2X |
Contact pin | Define the logic's signal contact pin code, if it differs from the one defined in the card. |
Function | If you use one function field, define a description of IO device functions in the field.
With outlet type IO devices you can add in the field a device to be controlled and a control function separated with a colon (:). For example Feeder extreme position down or CONVEYOR: FRONT (Outlet) |
Function1 | Enter a description of a IO device.
For example Feeder or CONVEYOR |
Function2 | Enter a description of the IO device's functions. With outlet type IO devices you
can add in the field the alternatives of control.
For example Extreme position down or FRONT |
Function3 | Enter a description of the IO device's additional data.
For example, capacitive sensor. |
Note: | To Note field you define additional information for schema depending on the IO
type, separated with a comma (,).
|
Cable routing |
|
Layout | To Lo i.e. layout field you define the status of IO device as for layout drawings.
If the device will not be in layout, the field is empty (--).
If you want a IO device of the row in question to appear in the selection list when the layout drawings are illustrated, you have to define 0 in the field. The layout drawing process will switch 0 to 1, when the device in question is added to the layout drawing. . |
Extra Data | To additional information field you can define free text and additional definitions
related to the row.
|
Device code | To device code field you define the material code of the device. Code is included in the device list. |
Cable code | To cable code field you define the material code of the cable. |
Listing | To listing field you define management of listings. 1: row is attached to I/O -list. 2: Code is included in the device list. 12 : row is attached to both lists. |