Mark Insulation in Isometrics
Piping Design
If you do not want to model insulation in 3D, you can specify insulation for an entire line position or individual part.
If the description or extra data field of an individual part reads erist or insul, the parts will feature tracing markings in isometrics.
Insulation for an Individual Part
- Double-click a component.
The COMPONENT DATA dialog box is opened.
- Enter the additional information in the Extra Data field: DN40 insulation 20 mm, for example.
- Select OK.
Insulation for an Entire Line Position
- Double-click a component.
The COMPONENT DATA dialog box is opened.
- Click the Line Position button.
The LINE POSITION DATA dialog box is opened.
- Select the following in the Insulation field: 20, for example.
- Select OK.
As an example, indicating insulation in isometrics.
As an example, insulation and tracing in isometrics.