Add Insulation to a Pipe Line

Piping Design

With the Insulation function, you can add insulation according to the additional selections, either for the entire pipeline, a specific section or an individual part of the pipeline. You can also add partial insulation to the pipeline starting from the point of the selected pipe and ending at the indicated point of the other selected pipe.

After specifying the target to be insulated, the function opens the Insulation Properties dialog box. Based on the selections made in the dialog box, the program offers an insulation thickness whose dimensioning is based on the standard PSK 3704.

Individual parts of the pipeline will have their own insulation part with item data. The insulations are shown as separate parts in the feature tree.

Adding insulation

  1. On the tab, select Insulation Add pipe line insulations.
  2. The program opens an additional function menu in the upper left corner of the model window

    Options in the additional function menu, starting from the top:
    1. This will target the entire pipe line
    2. This will target the section between clicked parts. Click the part from which the section starts and the last part of the section. With the additional option Add insulation of pipe only partially, you can display the start and end point between the end points of the selected pipe (partial insulation).
    3. Click the individual part to be insulated. With the additional option Add insulation of pipe only partially, you can display the start and end point between the end points of the selected pipe (partial insulation).
  3. Enter the required values in the Insulation Properties dialog box. Any fields marked in red are mandatory. The program remembers the values while it is running and uses them by default. When the program is restarted, the dialog box fields are empty by default.
    1. Type. Classification according to standard PSK 3703. The type is only selected for a pipeline, i.e. this option is missing from a duct line.
      1. Economic thermal insulation (TLE)
        1. When Economic thermal insulation is selected as the type, the Table field is also activated. The selections in the table affect the calculation of the insulation thickness according to the standard PSK 3704. The alternatives are:
          1. Basic level
          2. Good level
          3. Excellent level
      2. Protective insulation (TLE)
        1. When Protective insulation is selected as the type, the Emissivity field is activated in addition to the Temperature field. Enter the emissivity of the outer surface of the insulation in the field.

          Note: If the insulation covering is selected later, the emissivity of the covering must be entered in this field.
      3. Anti-freeze insulation (JE)
        1. When Anti-freeze insulation is selected as the type, the Time field is also activated. Standard PSK 3704, Table 7 defines how the insulation thickness is defined in this case.
        2. The fields Temperature and Table are not used in the case of Anti-freeze insulation.
      4. Process technical thermal insulation (PLE)
      5. Economical cold insulation (TKE)
      6. Anti-condensation insulation (HE)
      7. Process technical cold insulation (PKE), standard PSK 3712
    2. Temperature. Select a temperature by using the arrow on the right side of the field or enter a value in the field itself.
    3. DN size. Pipe nominal size. The program gets this information directly from the indicated pipe.
    4. Material. With the button you get a list of insulating materials according to standard PSK 3705. Material abbreviations, product type and category are completed according to the selection made.
    5. Product type, Class. Automatically set according to the selected insulating material.

    6. Thickness (mm). Based on the choices made above, the program calculates and proposes the insulation thickness according to the standard PSK 3704. You can also enter the thickness yourself if desired.

      Note: When the DN size of the pipe to be insulated cannot be found in the insulation standard database, the closest but larger size is used. For example, if you are insulating a pipe of DN 102 size, you will see the insulation thickness in the chart at DN 125 instead of DN 100

    7. Covering. If desired, you can select a covering for the insulation. At the same time, you can choose whether to make a separate item of the covering for the part lists.
    8. The material and thickness of the covering. With the button you get a list of covering materials according to standard PSK 3706. The thickness of the selected covering is automatically filled.
    9. Tracing. You can define tracing to be added inside the insulation. The tracing is taken into account in the isometric drawing as a dot-dash line. You can also enter a tracing label, which will be used as additional information for lists
    10. The option Transparent in assembly drawing makes the insulation transparent in the drawings. Only the outer edge of the insulation will be drawn with a thin dotted line.
  4. Select OK.

Note: This same function also allows you to insulate a duct line.