Panel Layers
Framer
The layers included in a floor or roof panel are determined by the system settings.
- Method 1: The panel is formed from the frame layer and the layers above and below it. This is the default method and is defined in the system settings with the keyword:
se_layer_mode = 1
The number of layers above and below the frame layer have default values set in the system settings with the keywords:se_above_layers - Number of layers above. The default value is 1.
se_below_layers - Number of layers below. The default value is 1.
- Method 2: Only the frame layer is included in the panel. The keyword in the system settings is:
se_layer_mode = 2
When you generate the panels by using the function Add a Panel in a Floor or Roof, you can change the method for forming the panels and change the number of layers above and below the frame layer with the auxiliary menu functions:
- Build panel based on current layers. The panel is formed from the frame layer and the layers above and below it. Select the number of layers by using a function in the auxiliary menu:
- Above layers - Enter the number of above layers in the text box.
- Below layers - Enter the number of layers below in the text box.
- Build panel into one layer. Only the frame layer is included in the panel.