Define a Non-updateable Part
When you add parts to a structure, the parts are added or regenerated to all the layers of the structure for which a framing tool has been defined and the parts of which are not protected. If necessary, you can set the desired parts as non-updateable, in which case they will not be regenerated, but will retain their properties and location.
This feature is available for the frame parts and sheets of a floor or roof panel or framing.
- Select one or more parts.
- Right-click to open the context-sensitive menu.
- Select Common Properties.
- Clear the selection Updateable Part. By default, this property is selected for all parts.
- Confirm by clicking OK.
You can highlight non-updateable parts in the model. See Mark Exceptional Parts.